Impact of ROI size on fractal dimension values in radiographs using a novel ROI selection method

MakaleYalnız künye
  • SDG 3 · Sağlık ve Kaliteli Yaşam

Özet

Objective: This study aimed to evaluate the effect of various sizes of regions of interest (ROIs) on fractal dimension (FD) in the evaluation of trabecular bone structure in dental radiographic images. Materials and methods: This study included 12 sheep hemimandibles. One set of digital images was obtained from each hemimandible using either periapical radiography, panoramic radiography, or cone-beam computed tomography (CBCT). Fractal analysis (FA) was conducted using ImageJ 1.3 software with the box-counting method on small, medium, and large ROIs obtained from each image, using a novel ROI selection method. Comparisons of FD values obtained from the three different ROI sizes were conducted within each radiographic image using repeated-measures ANOVA. Post hoc pairwise comparisons were performed with Bonferroni correction. Data were analyzed using Jamovi 1.6.23. Statistical significance was accepted as p < 0.05. Results: In periapical radiography, the FD values ​​obtained in small, medium, and large ROI sizes were 1.60 ± 0.02, 1.60 ± 0.01, and 1.65 ± 0.01, respectively (p < 0.001). In panoramic radiography, they were 1.45 ± 0.04, 1.71 ± 0.02, and 1.59 ± 0.01, respectively (p < 0.001), and in CBCT, they were 0.76 ± 0.07, 1.21 ± 0.04, and 1.48 ± 0.04, respectively (p < 0.001). Conclusions: The study demonstrates that FD is affected by the ROI size.

Anahtar Kelimeler

RDL Kalıcı Bağlantı (PID)
https://rdlopen.rawdatalibrary.net/r/adakent/10068Resmi atıflarda kullanılan kalıcı adres
Tam Kayıt
AlanDeğerDil
dc.contributor.authorYavuz, Esra
dc.contributor.authorTunc, Selmi
dc.date.accessioned2026-10-21T19:30:41.466832872Z
dc.date.available2026-10-21T19:30:41.466832872Z
dc.date.issued2026
dc.description.abstractObjective: This study aimed to evaluate the effect of various sizes of regions of interest (ROIs) on fractal dimension (FD) in the evaluation of trabecular bone structure in dental radiographic images. Materials and methods: This study included 12 sheep hemimandibles. One set of digital images was obtained from each hemimandible using either periapical radiography, panoramic radiography, or cone-beam computed tomography (CBCT). Fractal analysis (FA) was conducted using ImageJ 1.3 software with the box-counting method on small, medium, and large ROIs obtained from each image, using a novel ROI selection method. Comparisons of FD values obtained from the three different ROI sizes were conducted within each radiographic image using repeated-measures ANOVA. Post hoc pairwise comparisons were performed with Bonferroni correction. Data were analyzed using Jamovi 1.6.23. Statistical significance was accepted as p < 0.05. Results: In periapical radiography, the FD values ​​obtained in small, medium, and large ROI sizes were 1.60 ± 0.02, 1.60 ± 0.01, and 1.65 ± 0.01, respectively (p < 0.001). In panoramic radiography, they were 1.45 ± 0.04, 1.71 ± 0.02, and 1.59 ± 0.01, respectively (p < 0.001), and in CBCT, they were 0.76 ± 0.07, 1.21 ± 0.04, and 1.48 ± 0.04, respectively (p < 0.001). Conclusions: The study demonstrates that FD is affected by the ROI size.
dc.identifier.articlenumber102962
dc.identifier.doi10.1016/j.jormas.2026.102962
dc.identifier.eissn2468-7855
dc.identifier.issn2468-8509
dc.identifier.issue5
dc.identifier.pmid42633839
dc.identifier.scopus2-s2.0-105048802573
dc.identifier.urihttps://rdlopen.rawdatalibrary.net/r/adakent/10068
dc.identifier.volume127
dc.identifier.wosWOS:001868012400001
dc.language.isoen
dc.publisherElsevier Masson s.r.l.
dc.relation.ispartofJournal of Stomatology, Oral and Maxillofacial Surgery
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.subjectCBCT
dc.subjectDentistry
dc.subjectFractal analysis
dc.subjectFractal dimension
dc.subjectPanoramic radiography
dc.subjectPeriapical radiography
dc.subject.classificationDentistry, Oral Surgery & Medicine
dc.subject.otheranimal experiment
dc.subject.otheranimal model
dc.subject.otherArticle
dc.subject.otherbone structure
dc.subject.othercone beam computed tomography
dc.subject.othercontrolled study
dc.subject.otherdiagnostic test accuracy study
dc.subject.otherfemale
dc.subject.otherfractal analysis
dc.subject.otherfractal dimension value
dc.subject.otherimage analysis
dc.subject.otherimage processing
dc.subject.otherimage quality
dc.subject.otherimage segmentation
dc.subject.othermale
dc.subject.othernonhuman
dc.subject.otherpanoramic radiography
dc.subject.otherradiography
dc.subject.otherreceiver operating characteristic
dc.subject.otherregions of interest
dc.subject.otherROI selection method
dc.subject.othersensitivity and specificity
dc.subject.othersheep
dc.subject.othersoftware
dc.subject.otherthree-dimensional imaging
dc.subject.othertrabecular bone
dc.titleImpact of ROI size on fractal dimension values in radiographs using a novel ROI selection method
dc.typeArticle
dspace.entity.typePublication
rdl.citation.openalex0
rdl.citation.scopus0
rdl.citation.wos0
rdl.oa.statusclosed
rdl.sdgSDG03
rdl.source.indexSCOPUS
rdl.source.indexWOS
rdl.source.indexPUBMED
rdl.wos.indexScience Citation Index Expanded (SCI-EXPANDED)